Check the 'Possible Causes' listed above. Visually inspect the related wiring harness and connectors. Check for damaged components and look for broken, bent, pushed out, or corroded connector pins.
The cost to diagnose the P0133 2001 Toyota Corolla code is 1.0 hour of labor. The diagnosis time and labor rates at auto repair shops vary depending on the location, make and model of the vehicle, and even the engine type. Most auto repair shops charge between $75 and $150 per hour.
The response of the voltage signal from the sensor takes more than the specified time.
The front heated oxygen sensor (or O2 sensor 1) is placed into the exhaust manifold. It detects the amount of oxygen in the exhaust gas compared to the outside air. The heated oxygen sensor 1 has a closed-end tube made of ceramic zirconia. The zirconia generates voltage from approximately 1V in richer conditions to 0V in leaner conditions. The heated oxygen sensor 1 signal is sent to the Engine Control Module (ECM). The ECM adjusts the injection pulse duration to achieve the ideal air-fuel ratio.
Lean 0.35 V or less
Rich 0.45 V or more
Need more information on how to fix the P0133 2001 Toyota Corolla code? Get Access to Factory Service Manuals
Get the P0133 2001 Toyota Corolla code diagnosed by a professional: Find a repair shop in your area